辐射制冷文献检索系统 白色、彩色与透明辐射制冷 · 公开只读版 V3.2

用于准确确定被动辐射冷却功率的计量装置

Metrological setup for accurate determination of passive radiative cooling power
G. Lopardo;F. Bertiglia;Giuseppe Braccialarghe;Michael Florio;F. Girard;D. Giraudi;F. Santoro;Lorenzo Pattelli
作者
G. Lopardo;F. Bertiglia;Giuseppe Braccialarghe;Michael Florio;F. Girard;D. Giraudi;F. Santoro;Lorenzo Pattelli
期刊
Applied Thermal Engineering
年卷期页
2026,292: 130363
DOI
10.1016/j.applthermaleng.2026.130363
关键词
passive radiative cooling thermopile measurement uncertainty expanded uncertainty flow rate measurement SI traceability atmospheric window uncertainty budget
文献编号
RC-N-114
来源
批量扩充
中文信息
题名与中文摘要由 X-MOL 提供(平台机器翻译),英文原文见题名与英文摘要

中文简介

被动辐射冷却(PRC)能够通过大气透明窗将热量排散到冷天空,作为一种无功耗冷却策略,这一技术正受到越来越多的关注。然而,报告的冷却性能仍难以比较且常不可靠,主要原因是缺乏计量可靠的测量方法和定量不确定性评估。

英文摘要(原文)

Passive radiative cooling (PRC) enables heat rejection to the cold sky through the atmospheric transparency window and has attracted increasing attention as a power-free cooling strategy. However, reported cooling performances remain difficult to compare and often unreliable, primarily due to the lack of metrologically sound measurement methods and quantitative uncertainty assessment. In this work, a fluid-based calorimetric apparatus is designed according to a traceable metrological framework for the accurate determination of PRC cooling power. The system offers a compact panel-like geometry with uniform liquid flow distribution and employs high-sensitivity, SI-traceable sensors. In particular, the temperature difference between inlet and outlet water is measured directly using a calibrated multi junction differential thermocouple (thermopile) achieving an expanded uncertainty of just 12.4 mK, allowing to reliably measure also small temperature differences between the panel outlet and inlet ports. Together with a calibrated flow-rate measurement and a full uncertainty budget, the proposed design allows relative uncertainties consistently below 10% over almost the complete range of power densities relevant to PRC materials. Even at moderate fluxes, and in the presence of non-radiative heat transfer contributions, the setup achieves a significant improvement over the measurement…

题录(GB/T 7714)

Lopardo G, Bertiglia F, Braccialarghe G, 等. Metrological setup for accurate determination of passive radiative cooling power[J]. Applied Thermal Engineering, 2026, 292: 130363. DOI: 10.1016/j.applthermaleng.2026.130363.
打开原文